<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>DDC &#8211; Dwyer Instruments Blog</title>
	<atom:link href="https://blog.dwyer-inst.com/tag/ddc/feed/" rel="self" type="application/rss+xml" />
	<link>https://blog.dwyer-inst.com</link>
	<description>Manufacturing Excellence Since 1931</description>
	<lastBuildDate>Thu, 27 Apr 2017 17:22:57 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://blog.dwyer-inst.com/wp-content/uploads/2017/01/cropped-DwyerLogo_250x250-1-32x32.jpg</url>
	<title>DDC &#8211; Dwyer Instruments Blog</title>
	<link>https://blog.dwyer-inst.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Ask the Expert – High Duct Static Cutout Switch</title>
		<link>https://blog.dwyer-inst.com/2017/03/23/ask-the-expert-high-duct-static-cutout-switch/</link>
		
		<dc:creator><![CDATA[Andy Orlowski]]></dc:creator>
		<pubDate>Thu, 23 Mar 2017 15:19:20 +0000</pubDate>
				<category><![CDATA[Ask the Expert]]></category>
		<category><![CDATA[Building Automation Systems]]></category>
		<category><![CDATA[HVACR]]></category>
		<category><![CDATA[Markets]]></category>
		<category><![CDATA[Pressure]]></category>
		<category><![CDATA[alarm]]></category>
		<category><![CDATA[conduit]]></category>
		<category><![CDATA[DDC]]></category>
		<category><![CDATA[delay]]></category>
		<category><![CDATA[DPDT]]></category>
		<category><![CDATA[fan]]></category>
		<category><![CDATA[field adjustable]]></category>
		<category><![CDATA[high duct static cutout]]></category>
		<category><![CDATA[lag]]></category>
		<category><![CDATA[lead]]></category>
		<category><![CDATA[low differential pressure switch]]></category>
		<category><![CDATA[manual reset]]></category>
		<category><![CDATA[mechanical]]></category>
		<category><![CDATA[no power]]></category>
		<category><![CDATA[set point]]></category>
		<category><![CDATA[setpoint]]></category>
		<guid isPermaLink="false">https://blog.dwyer-inst.com/?p=677</guid>

					<description><![CDATA[Question: Does Dwyer offer a differential pressure switch with manual reset for high duct static cutout applications? Answer: For high duct static cutout applications, Dwyer recommends our Series 1831 DPDT Low Differential Pressure Switches with Manual Reset.  The Series 1831 is purely mechanical, requiring no power to operate the DPDT switch, and can be set in &#8230; <p class="link-more"><a href="https://blog.dwyer-inst.com/2017/03/23/ask-the-expert-high-duct-static-cutout-switch/" class="more-link">Continue reading<span class="screen-reader-text"> "Ask the Expert – High Duct Static Cutout Switch"</span></a></p>]]></description>
		
		
		
			</item>
	</channel>
</rss>
